Parameter description
Parameter manual b maXX
®
1000
Document no. 5.07004.03 Baumüller Nürnberg GmbH
68
of 208
4.3
P0911
Speed can be scaled by the user with this parameter.
Example:
Speed set value = 18000 rpm
ZP0911– = 2.00
⇒ Speed set value = 36000 rpm
P1000
With this parameter you determine the operation mode of the drive.
Switching between operation modes is possible with drive inhibited (offline mode) and
also drive enabled (online mode).
P0911
Geschwindigkeit Multiplikator CANopen/Modbus 0 to
EE Speed multiplier CANopen/Modbus 1.00
ON BM_u_Speed MultiplierCANModbus 100:1 -
P1000
Soll-Betriebsart 1 to 249
EE Operation mode set value 6
STOP BM_u_OperationModeSetValue 1:1
Value Meaning
249 Motor parameter auto tuning
2 Speed setting for ramp function generator
5 Jog operation
6 Operation mode only for motion control