Parameters
Application handbook Servo pump function V1 for BM5000
Document No.: 5.17002.02
59
of 76
6
176.19 Value analog output 4
FLOAT -11 V to +11 V
Analog output 4 of add-on module SVP is hard-linked to motor temperature (P128.3).
Scaling: 0 V -10 V = 200 °C
176.60 User scaling factor add-on module AI1
FLOAT -1000000000.000 to 1000000000.000
Scaling factor volume set value in case of analog set values.
176.61 User offset add-on module AI1
FLOAT -10 V to +10 V
Offset volume set value in case of analog set values.
176.62 User filter add-on module AI1
INT 0 to 3000
Filter volume set value in case of analog set values.
176.63 User scaling factor add-on module AI2
FLOAT -1000000000.000 to 1000000000.000
Scaling factor volume set value in case of analog set values.
176.64 User offset add-on module AI2
FLOAT -10 V to +10 V
Offset pressure set value in case of analog set values.
176.65 User filter add-on module AI2
INT 0 to 3000
Filter pressure set value in case of analog set values.