Reading in of pressure and volume set/actual values
Application handbook Servo pump function V1 for BM5000
Document No.: 5.17002.02 Baumüller Nürnberg GmbH
22
of 76
3.2
3.2.2 Field bus combined with add-on module SVP
In the case the pressure and volume set value are set via field bus parameters:
m Volume set value interface:
ZP177.42 Q Set value field bus DINT Scaling: ml/min
m Pressure set value interface:
ZP177.20 P set value field bus DINT Scaling: mBar
The pressure actual value is provided via analog module SVP-001-00X in slot B of the
b maXX controller. The pressure actual value can be read in from 0/4 - 20 mA or 0 - 10 V.
Figure 18: Field bus combined with add-on module SVP
Pressure