Parameter description
Application handbook Servo pump function V1 for BM5000
Document No.: 5.17002.02 Baumüller Nürnberg GmbH
64
of 76
6.3
177.41 n/Q set value scaled
DINT -32768 to +32767
Set volume value according to scaling through the scaling divisor parameter ZP177.40
. Display in the ProDrive depending on the settings on page „Servo pump - general“ in
rpm or in l/min.
Scaling: 32767 Inc = Motor maximum speed * 2
177.42 n/Q set value bus
DINT -2147483.648 to +2147483.647
Set volume value from a field bus chart.
Scaling: 1 Inc = 1 ml/min
177.62 Integral action time nominal
DS-support UINT 0 to 1000 ms
Integral action time of pressure controller.
177.119 P actual value
INT -32768 to +32767
Actual pressure value for PI pressure controller.
Depending on the active sensor for pressure control (compare bit 7 in ZP177.3) „P ac-
tual value“ is written by „P actual value sensor 1“or „P actual value sensor 2“.
Scaling: 32767 Inc = ZP177.6 or ZP177.7
177.120 P set value
INT -32768 to +32767
Set pressure value for PI pressure controller
Scaling: 32767 Inc = ZP177.6 or ZP177.7
177.122 P-gain
DS-support UINT 0 to 65535
P-Gain value of PI pressure controller
Scaling: 100:1