177.125 Integral part PI controller
DINT -2147483648 to +2147483647
Integral part PI pressure controller
Scaling: 1073741824 Inc = Max. drive Speed (P110.13)
177.144 P Set value minimum
INT 0 to 32767
Limit for Pressure set value.
If actual Pressure is smaller than „P Act value minimum“ and set pressure is smaller than
„P Set value minimum“ then speed set value is set to 0.
Scaling: 32767 Inc = ZP177.6– or ZP177.7–
177.145 P Act value minimum
INT 0 to 32767
Limit for Pressure actual value.
If actual Pressure is smaller than „P Act value minimum“ and set pressure is smaller than
„P Set value minimum“ then speed set value is set to 0.
Scaling: 32767 Inc = ZP177.6– or ZP177.7–
177.165 Pump protection rest waiting time
UDINT 0 to 65535 ms
Actual value for wait counter pump protection functionality
Scaling: 1 Inc = 1 ms
177.166 Pump protection recognition time
DS-support INT 100 to 10000 ms
Recognition time for wait counter pump protection functionality.
Scaling: 1 Inc = 1 ms