177.167 Pump protection n/Q recognition threshold
DS-support DINT 0 to 2147483647
Speed threshold for pump protection functionality.
Scaling: 1073741824 Inc = Max. drive speed (P110.13)
177.168 Pump protection P actual value threshold
DS-support DINT -32768 to +32767
Actual pressure threshold for pump protection.
Scaling: 32767 Inc = ZP177.6– or ZP177.7–
177.169 n/Q actual value inverted
UDINT 0 to 4294967295
Absolute value of actual speed.
Scaling: 1073741824 Inc = Max. drive speed (P110.13)
177.173 SP Speed set value positive limit
DS-support FLOAT 0 to 166666.6667 rpm
Positive Speed Limit.
This parameter overwrites P18.71 „Speed Set value positive limit“.
177.174 SP Speed set value negative limit
DS-support FLOAT -166666.6667 to 0 rpm
Negative Speed Limit.
This parameter overwrites P18.72 „Speed Set value negative limit“.