EasyManua.ls Logo

Baumuller b maXX BM4 Series - Connection Cable for (BM4-F-)ENC-05

Baumuller b maXX BM4 Series
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connection diagrams
Instruction Handbook b maXX (BM4-F-)ENC-XX (Encoder module)
Document No.: 5.01042.12 Baumüller Nürnberg GmbH
60
of 102
7.3
Construction guidance connection cable for (BM4-F-)ENC-05
m Sine cosine incremental encoder with EnDat 2.1
®
-interface
The connection cable can be ordered from Baumüller Nürnberg GmbH (see ZEnDat® 2.1
encoder cableon page 91).
Construction guidance:
1 Use the following materials:
m Cable: 14 wires (recommendation: 6 x (2 x 0.14 mm
2
) + 2 x 0.5 mm
2
), twisted pairs,
pairs layer-twisted, tinned Cu transfer, Cu braiding with at least 85
% opt. overlap.
m Sub-D connector. 15-pin, male
m Circular connector: 17-pin, female (e. g. Interconnectron)
2 Connect the cable shield laminar with the shield of the Sub-D connector.
Figure 10: Connection cable for (BM4-F-)ENC-05