7.3
Construction guidance connection cable for (BM4-F-)ENC-05
m Sine cosine incremental encoder with EnDat 2.1
®
-interface
The connection cable can be ordered from Baumüller Nürnberg GmbH (see ZEnDat® 2.1
encoder cable– on page 91).
Construction guidance:
1 Use the following materials:
m Cable: 14 wires (recommendation: 6 x (2 x 0.14 mm
2
) + 2 x 0.5 mm
2
), twisted pairs,
pairs layer-twisted, tinned Cu transfer, Cu braiding with at least 85
% opt. overlap.
m Sub-D connector. 15-pin, male
m Circular connector: 17-pin, female (e. g. Interconnectron)
2 Connect the cable shield laminar with the shield of the Sub-D connector.
Figure 10: Connection cable for (BM4-F-)ENC-05