DV 14307.03 Issue 1 09/2013 Page 1-15
Condition
Section
Cat.
Description
Temperature and Altitude
4.0
C4
Ground Survival Low
Temperature
4.5.1
C4
-55 deg C
Short-Time Operating Low
Temperature
-20 deg C
Low Operating Temperature -20 deg C
High Ground Survival
Temperature
4.5.2
+85 deg C
High Short-Time Operating
Temp.
+70 deg C
High Operating Temp. +55 deg C
In-flight Loss of Cooling 4.5.5 - No forced cooling required
Altitude 4.6.1
C4
35000 ft
Decompression 4.6.2 N/A
Overpressure 4.6.3 N/A
Temperature Variation
5.0
B 5 deg C per minute
Humidity
6.0
A Standard
Shock and Crash Safety
7.0
B
Fixed-wing and Helicopter,
standard
Vibration
8.0
S+U
Test curve M+G Fixed-wing +
Helicopter
Explosion Proofness
9.0
- N/A
Water Proofness
10.0
Y -
Fluids Susceptibility
11.0
- N/A
Sand and Dust
12.0
- N/A
Fungus Resistance
13.0
- N/A
Salt Spray
14.0
- N/A
Magnetic Effect
15.0
Z 1 degree deflection at 0.3 m
Power Input
16.0
B
DC installations with
battery of significant
capacity
Voltage Spike
17.0
A
High degree of protections
against voltage spikes

Table of Contents

Other manuals for Becker RT6201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Becker RT6201 and is the answer not in the manual?

Becker RT6201 Specifications

General IconGeneral
BrandBecker
ModelRT6201
CategoryTransceiver
LanguageEnglish

Related product manuals