INTEGRA® / E-1063
1MANUL102 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 5-15
Chapter 5 Operator Interface/Wash Setup Screens
Setup
Setup / POS (Point of Sales) Loading
Max Queue Amount – Limits the number of washes the Queue will stack. This value is usually set to 1
when the E-1063 is not visible.
1. Screen Accept: This function toggles between “Screen Accept Only” and “Screen/Alt Accept”
• Alternative Accept Disabled: When selected, only the screen and/or the Operators Station will load
the selected “stand-by” package into the QUEUE.
• Alternative Accept Only (Alternative Accept): When selected, Screen, Operators Station and
alternative method will load “Stand-by” into the QUEUE. The alternative load method will be either by
Input or Timed. These two methods are covered below.
2. Alt Accept: This function toggles between “Input” and “Timed”.
• Input: Typically an “E-Z Load Photo Eye”. The stand-by package will be accepted into the QUEUE
when the “E-Z Load Photo Eye” is broken.
• Timed: The stand-by package will be accepted into the QUEUE according to the user defined time
selected (measured in seconds). This function is typically used in Unattended, 1 Step systems.
3. E-Z Load / Tire Eval: Here you determine if the “E-Z Load Photo Eye” will be used for tire evaluation or not.
The E-Z Load Photo can be selected to be involved in the Tire Evaluation of the Treadle. If the “E-Z Load
Photo” is indeed used, the Treadle will only evaluate tires when the Photo Eye has been broken.
Note: See recommended initial setting for additional indication of setting per loading style in
Chapter 6.