Important: The Lift controls include an Emergency Stop Button, which will stop the Lift
immediately when activated. This is not the same thing as a Power Disconnect
Switch.
The Power Disconnect Switch is a National Electrical Code (NEC) requirement. The Disconnect Switch
is designed to completely interrupt electrical power to the Lift.
Install a Disconnect Switch that is UL-Listed and appropriately rated for the electrical load presented
by the Power Unit and the incoming electrical power.
The Power Disconnect must be readily accessible and installed so that it is within easy reach of the Lift
Operator. The Disconnect must be clearly and legibly marked. The Switch itself and its Conduits or
Wiring should not interfere with any of the Lift’s mechanical functions or controls.
The figure below details one possible location for the Power Disconnect, above the connection for the
Control Panel. Refer to the Wiring Diagram and Control Panel Wiring Diagram for further
information.