PL-6000DC/DCX Two-Post Parking Lift 66 P/N 5900273 — Rev. A6 —July 2024
Power Unit
Hydraulic Cylinder
Cylinder moves in short jerks.
Air in the Hydraulic System.
several times to bleed the air
Friction due to lack of
lubrication or misalignment.
Poor seal alignment on Cylinder
Rod.
Severe leaking of the Cylinder.
Friction resistance due to dirty
Hydraulic Fluid.
Elements and replace Hydraulic
Oil and Filter.
One-Way valve or throttle valve
failure in cushion device
Repair one-Way valve/throttle
valve.
Problem Possible cause Solution
maintained after Platform
is Lifted.
Solenoid Valve element is
blocked.
Clean or replace Solenoid valve.
Outlet fitting is not fastened, or
seal is damaged.
Reattach Outlet Pipe or replace
seal.
when lowering.
Throttle Valve is not adjusted.
Throttle valve is blocked.
Solenoid Valve is blocked.
Cylinder does not retract
at all when lowering.
Lowering solenoid is inoperative
or supply voltage is too low.
Replace Solenoid Coil or supply
correct voltage to the coil.
Lift is too loud, or Lift is
making an abnormal
noise when Power Unit is
on.
Low Hydraulic Fluid allows air into
pump and system.
Refill Reservoir. Run the Lift up
and down several times to bleed
Pressure Relief Valve is triggered.
inoperative.
Replace Pressure Relief Valve.
Voltage drop due to wrong wire
gauge for distance.
Replace the wire with the correct
wire gauge for the distance.
Starting Capacitor inoperative.
Replace starter Capacitor.