H22: Speed Search Select
Range: 0-15 (Default: 0)
Description: This function is used to catch a spinning motor after Power ON, Fault Reset
and Instant Power Failure without waiting for the motor to stop. The speed
search gain should be set after considering the inertia moment (GD2) and
magnitude of torque of the load. F37 [Load Inertia] must be set to the
correct value to make this function operate properly.
This parameter will estimate the motor speed and try to match it's speed
rather than starting at 0Hz.
The following table shows 4 types of Speed Search Selections.
88
6 - Parameter Descriptions
Run
command
Reset
Frequency
When H21 is 0 When H21 is 1
H22
Speed
Search
during H20
[Power ON
Start]
Speed
Search
during
Instant
Power
Failure
Restart
Speed
Search
during H21
[Restart
after fault
reset]
Speed
Search
during
Acceleration
Bit 3 Bit 2 Bit 1 Bit 0
0----
1---ü
2--ü -
3--üü
4-ü --
55ü - ü
6-üü -
7-üüü
8 ü ---
9 ü --ü
10 ü - ü -
11 ü - üü
12 üü --
13 üü - ü
14 üüü -
15 üüüü