EasyManua.ls Logo

BFT CDS 1.3 - Installation C Controlled Entry and Exit

BFT CDS 1.3
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 34 -
Control unit
EN
- Connect the N.O. contact of the coil S1 and S2 receiver to
input PDM.
- The dimensional values of the loops are only approximate.
We suggest installing the MAK-2 metal mass detector.
*
ENGLISH
This solution is recommended when you want to enter a reserved area in both directions activating a recognition command (radio control,
proximity key, magnetic keys, etc.).
The vehicle approaches the reserved area.
When the vehicle is on loop S1 the
device will move down only after a
recognition command.
If the device is moving back up and
you want to lower it again the ve-
hicle must be on loop S1 and then
you must activate the recognition
command.
When the vehicle is no longer on
loop S2 the device will move back
up automatically after an adjustable
pause time.
The vehicle approaches the reserved
area.
ENTRY
EXIT
DIMENSIONS
When the vehicle is on loop S2 the
device will move down only after a
recognition command.
If the device is moving back up and
you want to lower it again the ve-
hicle must be on loop S1 and then
you must activate the recognition
command.
Loops S1 and S2 also have a safety function in that they will not let the device move all the time the vehicle is on top.
When the vehicle is no
longer on loop S1 the
device will move back
up automatically after
an adjustable pause
time.
12.3
INSTALLATION C
CONTROLLED ENTRY AND EXIT
PARAMETER DATA DESCRIPTION
=
 
Functioning logic: Automatic
 
Pause time
 
Opening consent and pause time reset
 
Radio channel 1: Open

Table of Contents