Operating instructions SC II Operation
61429850113 en-US 71 / 107
6.25.4 PLU type:"By-count fixed weight"
Menu setting
- In configuration, activate "Price Labeling" in the Operating mode menu and "Weight for
fixed price PLU" either with or without weight printout in the Printer menu.
- In PLU maintenance, enter the PLU type "By-count FW" and the fixed weight in "Tare
+Weight". Switch "Unit price return account" on or off.
Operating procedure
Call up the "By-count fixed weight" ar-
ticle, e.g. <PLU 2>.
Illustration58: By-count-Fixed weight
Price labeling
Calculated unit price (e.g. 5.00 EUR/kg) is
not displayed but printed on the label.
The selling price can be overwritten.
Multiplication is supported.
Enter number of pieces, e.g. 5.
Illustration59: Enter Number of pieces
Fixed weight and selling price correspond to
5 pieces
.
Register using operator key, e.g.
<OP1>.
6.26 PLU type: "By count"
By-count PLUs are piece articles with a saved number of pieces. The selling price relates to
the number of pieces. The number of pieces is calculated and printed on labels when "Unit
price return calculation" is activated.
Adjustable first rounding for By-count in the "Country currency"
menu.
Select 2 9 1 1
Menu setting
- In menu "PLU maintenance" / "Prices" select menu item "PLU type [By-count]".
- Enter the quantity in the "Piece number" menu. Activate the "Price overwrite" menu item.
Activate the "Unit price return calculation" menu item. Select 1 1 2 / Dep. No. / PLU No. /
1