EasyManua.ls Logo

BK Precision 2190D - Page 98

BK Precision 2190D
159 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
84
menu”.
Table 3.42 Types of Measurements
Measure Type
Description
Vmax
The most positive peak voltage measured over the
entire waveform.
Vmin
The most negative peak voltage measured over the
entire waveform.
Vpp
Measures the absolute difference between the
maximum and minimum peaks of the entire
waveform.
Vtop
Measures the highest voltage over the entire
waveform.
Vbase
Measures the lowest voltage over the entire
waveform.
Vamp
Voltage between Vhig and Vlow of a waveform.
Vavg
The arithmetic mean over the first cycle in the
waveform.
Mean
The arithmetic mean over the entire waveform.
Crms
The true Root Mean Square voltage over the first
cycle in the waveform.
Vrms
The true Root Mean Square voltage over the entire
waveform.
ROVShoot
Defined as (Vmax-Vhig)/Vamp after the
waveform rising.
FOVShoot
Defined as (Vmin-Vlow)/Vamp after the
waveform falling.
RPREshoot
Defined as (Vmin-Vlow)/Vamp before the
waveform rising.

Table of Contents