Installation
9
Utility Connections
ELECTRICAL CONNECTIONS
Beforemakingany electricalconnectionstothese
units, check that the power supplyis adequatefor
the voltage, amperage, and phase requirements
stated on the rating name plate mounted on the
right side of the unit.
U.S. and Canadian installations
All ovens, when installed, must be electrically
groundedinaccordancewithlocalcodes,orinthe
absenceoflocalcodes,withtheNationalElectrical
Code, ANSI/NFPA70---Latest Edition and/or Cana-
dian National Electric Code C22.2 as applicable.
General export installations
Installation must conform with Local and National
installation standards.
WARNING!!
On 480V units,the fan should be checked
to ensure the proper rotation after con-
necting the appliance. See Figure 5. If the
fan turns in the wrong direction, the ap-
pliance will not function properly and
damage to the unit can occur. Improper
connection of the appliance renders the
warranty invalid.
Direction Of Fan Rotation
Figure 5
NOTE: Disconnect the power supply to the unit
before servicing.
NOTE: All manual resets should be restored be-
fore connecting power to the appliance.
WARNING!!
Improper installation will invalidate your
warranty.