Maintenance
21
Spray Bottle Operating Procedure
1. Unscrewthesprayerheadandfillthecontain-
ertotheMAXmark.Screwtheheadassembly
on firmly to ensure an airtight seal. The liquid
mustbecleanandfree fromforeignma tter.Do
not overfill - space must be left for compress-
ing air.
2. Tobuilduppressure,pumpapproximately20
fullstrokesw hen thecontainerisfilledwithliq-
uid. The higher the pressure, the finer the
spray. If the container is only partially filled,
then more pumping is required to compress
the additional air space.
3. Tospray, depress the triggerwith yourthumb.
4. After a period of spraying, the pressure will
drop. Restore the pressure by operating the
air pump.
5. Release pressure after use by inverting the
spray head and depressing the trigger or by
slowly unscrewing the spray headassembly
which will allow airto escapefrom aroundthe
filling aperture.
6. Afteruse, rinsethespraybottlewithcleanwa-
terandcheckthattheholeinthenozzleisper-
fectly clean and clear. Warm water (not hot)
used with a household detergent is a useful
cleaning agent for this purpose.
NOTE: Further information can be found in the in-
struction leaflet supplied with your spray
bottle.
Service Parts:
Complete spray bottle P/N R0006
Spray nozzle repair kit P/N R6332
WARNING!!
Protective clothing and eye wear should
be worn while using cleaning agents.
MAX
Spray Head
Pressure Pump
Spray Trigger
Pressure
Vessel
Pump
Clean the pump 2 or 3 times per week with warm water
Figure 15