Maintenance
23
Decalcification
1. TurntheModeSelectionSwitch(1)tothe
STEAM mode. Wait until steam is produced.
This will ensure that the w ater in the steam
generator is hot.
2. TurntheModeSelectionSwitch(1)tothe
COOL DOWN mode and leave the door open.
Let the oven compartment cool to 150_F
(66_C). This ensures that the Drain/Flush
switch will function in STEP 8.
3. TurntheModeSelectionSwitch(1)toOFF.
4. In a suitable size container, mix together the
deliming solution and hot tap water. Refer to
the following chart for the proper mixture:
Model
Deliming
Solution
Hot Tap Water
COS-6 12 oz. 3quarts
COS-101 18 oz. 1-1/4 gallons
COS-101S 18 oz. 1-1/4 gallons
NOTE: These volumes are approximate. You
may need more or less hot water de-
pending on your site.
5. Remove the Deliming Port Cap from the De-
liming Inlet (5). Attach the supplied Funnel
and Hose Assembly (3) to the deliming inlet.
6. Open the Deliming Port Valve (2) and pour in
the deliming mixture. Stop pouring when the
funnel stops draining. This is the correct
amountforyoursite.
7. ShuttheD elimingPortValve(2).Screw onthe
DelimingPortCap.Letthemixturestandfor20
minutes. In a reas of the countrywith hard w a-
ter, allow the mixture to stand for 1 hour.
8. Depress and hold the Drain/Flush Switch (4)
in the FLUSH position for 90 seconds. This
completes t he deliming procedure.
3
2
1
4
close
open
5
Figure 16