Parameter
Settings
No.
Description
Min.
Max.
Fact. sett.
1192 Peak current 0.01 % I
FI,N
100 000 %
oâ‹…I
FI,N
100 % I
FI,N
I
FI,N
: Nominal value of Frequency inverter
o: Overload capability of Frequency inverter
10.2.8 Change sense of rotation
The parameter Change sense of rotation 1199 reverses the rotating direction of the
motor.
Operation mode 1199
Positive Set value
Negative Set value
0 -
Off
Motor rotates forward
(clockwise)
Motor rotates reverse
(anti clockwise)
1 -
On
Motor rotates reverse
(anti clockwise)
Motor rotates forward
(clockwise)
BONFIGLIOLI VECTRON defines with view on the motor A side and correct connection
of the motor phases the sense of rotation clockwise (forward) with a positive set value.
With a changed sense of rotation, the motor reverses with the same set value. Existing
gear boxes and transmissions have to be considered.
The sense of rotation can only be changed while the output stage is inhibited.
With the parameter Change sense of rotation 1199 the sense of direction of the com-
plete system (motor control and encoder evaluation) is reversed.
When the sense of direction is different between motor and encoder, this can be
changed by two actions:
1.) Change the track A and track B at the encoder inputs at the terminals of ACU.
2.)
Change the evaluation of the sense of rotation of the connected encoder with
parameter 490 respectively 493.
10.3 Internal values
The following parameters are used for internal calculation of motor data and do not
require any set-up.
Parameter
Parameter
No. Description No. Description
399 Internal value 01 706
Internal value 08
402
Internal value 02
707
Internal value 09
508
Internal value 03
708
Internal value 10
702
Internal value 04
709
Internal value 11
703
Internal value 05
745
Internal value 12
704
Internal value 06
798
Internal value 13
705
Internal value 07
06/13 Operating Instructions ACU 127

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI ACTIVE Cube ACU 201-01 and is the answer not in the manual?

BONFIGLIOLI ACTIVE Cube ACU 201-01 Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelACTIVE Cube ACU 201-01
CategoryInverter
LanguageEnglish

Related product manuals