7.5 Copy Menu (CPY)
With the copy function of the control unit you can copy parameter values from the
frequency inverter to a non-
volatile memory of the control unit (upload) and store
(download) them to a frequency inverter again.
The copy function makes the parameterization of recurring applications much easier.
The function archives all parameter values, regardless of access control and value
range. The memory space available in the control unit for the files is dynamically
scaled to match the scope of the data.
The Copy Menu (CPY) is accessible in control level 3. The control level can be adjusted,
if necessary, via parameter
Control Level 28.
7.5.1 Reading the Stored Information
When you open the CPY menu branch, the data stored in the
control unit are read out. This process takes a few seconds.
During this time, init
and a progress indicator are displayed.
After the initialization in the copy menu, the function can be
selected.
If the information stored in the control unit is not valid, the
initialization is stopped and an error message is displayed.
In this case, the memory in the control unit must be formatted
as follows:
• Use the ENT key to confirm the error message.
• Use the arrow keys to select the function FOr.
• Use the ENT key to confirm the selection.
During the formatting process, FCOPY and a progress in-
dicator are displayed.
The process takes a few seconds. When the process is
complete, the message rdY is displayed.
• Confirm the message by pressing the ENT key.
Now, you can select the copy function as described in the fol-
lowing.
06/13 Operating Instructions ACU 91

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI ACTIVE Cube ACU 201-01 and is the answer not in the manual?

BONFIGLIOLI ACTIVE Cube ACU 201-01 Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelACTIVE Cube ACU 201-01
CategoryInverter
LanguageEnglish

Related product manuals