Functions and operation
EN
22 www.bora.com
The cooktop extractor was switched on
T
The automatic after-run function is started.
T
As soon as the after-run period is complete, the appliance is
automatically switched off.
T
The display switches off after 10 seconds.
The cooktop was switched on
T
is shown in the control knob display for previously active and still
hot cooking zones displayed (residual heat indicator).
T
If there is no longer any residual heat, the display will switch off
after 10 seconds.
5.3
Operating the cooktop
extractor
5.3.1
General operating instructions for
the cooktop extractor
Both cooktop extractor functions and system functions can be
operated using the cooktop extractor control knob.
The cooktop extractor must only be operated with BORA
cooktops.
The cooktop extractor must only be operated when the
grease filter components are installed.
Recommendations for efficient vapour extraction
u
In the case of tall cooking pots, place the lid on at an angle so that
the cooking vapours are guided towards the cooktop extractor.
u
Only operate the cooktop extractor at the minimum power level
required for effective vapour extraction. This enables you to
improve the performance of the odour filters in recirculation mode.
u
Only operate the hob at the minimum power level required for
cooking. This reduces the cooking vapours and the power
consumption.
u
Avoid strong drafts.
Restricted functions when using the cooktops without a
cooktop extractor
If cooktops are installed and operated without a cooktop extractor,
only limited functions will be available. The following functions will not
be available:
T
System functions
T
Pause function
T
Short-time timer
T
Child lock
T
All settings/functions in the configuration menu
5.3.2
Setting the fan power level
The power levels are controlled by turning the knob ring to the
desired power level (electronic power adjustment).
Increasing the power level
u
Turning the knob ring clockwise
Reducing the power level
u
Turning the knob ring anticlockwise
T
The selected power level is shown in the display on the extractor
control knob.
Fig.5.6
Setting the fan power level
5.3.3
Fan power setting
When the power setting is activated, maximum extractor power is available
for a predefined time. This power setting makes it possible to suction away
high levels of cooking vapours more quickly. After 10 minutes, the power
setting is automatically switched back to power level 9.
Activating the power setting
u
When the power setting is activated, maximum extractor power is
available for a predefined time.
T
This power setting makes it possible to suction away high levels of
cooking vapours more quickly.
Deactivating the fan power setting
The fan power setting is deactivated early if another power level is set.
5.3.4
Automatic after-run
When the extractor is switched off, the automatic after-run function is
activated. The cooktop extractor continues to run at a lower level and
switches off automatically after 20 minutes. The display switches off
10 seconds later.
Switching off the automatic after-run early
u
touching the touch surface of the control knob
or
u
turning the knob ring anticlockwise
T
The after-run function will be switched off early and the display will
go out after 10 seconds.
BORA expressly recommends use of the cooktop extractor
after-run function.
5.4
Cooktop extractor function
menu
Every appliance offers different additional functions. These can be
selected and activated via a function menu. Only the functions
available for each type of appliance are shown in the corresponding
function menu. The cooktop extractor function menu contains both
system functions and cooktop extractor functions.
There is a total of 5 additional functions to choose from:
Menu item Function System
function
Cooktop extractor
function
Extractor cleaning 3
Short-time timer 3
Automatic extractor
function
3
Child lock 3
Show and reset filter status
3
Tab.5.2
Overview of cooktop extractor function menu