3.3 Performance Characteristics
– Intelligent access manager for 1 - 8 entrances (for example doors, man traps, barriers)
– Controlled by an AMC2 via RS-485
– Host address selectable using DIL sliding switch.
– Four possible configurable host interfaces:
– Ethernet (= standard)
– RS-485 2-wire
– RS-485 4-wire
– RS-232
– Two possible configurable host interfaces:
– Ethernet (= standard)
– RS-485 2-wire
– Reader interfaces
– Reader interfaces
– four two Wiegand interfaces
– Reader interfaces
– two Wiegand interfaces
– one RS-485 interface
– Reader interfaces
– four RS-485 interfaces
– Reader interfaces
– two RS-232 interfaces
– Slave interface
– one RS-232 for additional control (biometrical or long distance reader)
– Eight relay outputs
– voltage free, power is supplied externally (dry mode)
– powered by internal power supply (wet mode)
– Eight analog inputs with internal power supply
– 8 relay outputs
– voltage free, power is supplied externally (dry mode)
– powered by internal power supply (wet mode)
– 8 analog inputs with internal power supply
– Battery buffered SRAM and real time clock (RTC)
– Pluggable Compact Flash card
– Liquid Crystal Display
– Transfer rate host interface RS-485: 38,4 kBit/s
– Transfer rate host interface RS-232: 38,4 kBit/s
– Transfer rate host interface Ethernet: 10/100 Mbit/s
– Transfer rate to the extension interface: 9,6 kBit/s
– Transfer rate reader interface RS-485: 9,6kBit/s
– Transfer rate reader interface depends on the connected device.
– Self regulating transmit/receive switching
– Supply voltage: 10 V to 14 Vdc,
– Max current load: 3A
– Power supply:
– 10V - 30Vdc - max. 3 A
– or over the RS-485 host connector
– Information about the inputs and outputs on the display of the AMC2 controller
– Tamper contact for external covers