38 en | System setup DIVAR IP all-in-one 6000
2022-10 | V02 | F.01U.407.903
Installation manual
Bosch Security Systems B.V.
8.5 Signing in to the administrator account
Signing in to the administrator account in BVMS operation mode
To sign in to the administrator account in BVMS operation mode:
1. On the BVMS desktop, press CTRL+ALT+DEL.
2. Press and hold the left SHIFT key immediately after clicking Switch User.
3. Press CTRL+ALT+DEL again.
4. Select the BVRAdmin user and enter the password that was set during the system setup.
Then press ENTER.
Note: To go back to the BVMS desktop, press CTRL+ALT+DEL and click Switch user or Sign
out. The system will automatically go back to BVMS desktop without a system restart.
Signing in to the administrator account in VRM or iSCSI operation mode
To sign in to the administrator account in VRM or iSCSI operation mode:
4 On the Windows sign-in screen, press CTRL+ALT+DEL and enter the BVRAdmin password.
8.6 Configuring new hard drives
DIVARIPall-in-one units that come pre-equipped with hard drives from factory are ready to
record out-of-the-box.
Hard drives that have been added to an empty unit need to be configured before using them
for video recording.
To configure new hard drives for video recording, you must do the following:
1.
Configuring RAID5, page 38
.
2.
Recovering the unit, page 39
.
8.6.1 Configuring RAID5
i
Notice!
The initial RAID configuration is not necessary for units with pre-installed hard drives. Units
with preinstalled drives are delivered with a default configuration.
To configure RAID5:
1. Install all hard drives.
2. Turn on the unit and press Del to enter the BIOS setup.
3. In the BIOS setup, navigate to the tab Advanced.
4. Select the option BROADCOM <SAS 3908> Configuration Utility, then press Enter.
5. In the ACTIONS: section, select the option Configure, then press Enter.
6. In the next dialog box, select the option Create Virtual Drive, then press Enter.
7. In the next dialog box, select the option Select RAID Level, then press Enter.
The Select RAID Level dialog box is displayed
8. In the Select RAID Level dialog box, select RAID5, then press Enter.
9. In the CONFIGURE VIRTUAL DRIVE PARAMETERS: section, select the option Strip Size,
then press Enter.
The Strip Size dialog box is displayed.
10. In the Strip Size dialog box, select 64 KB, then press Enter.
11. In the CONFIGURE VIRTUAL DRIVE PARAMETERS: section, select the option Write
Policy, then press Enter.
The Write Policy dialog box is displayed.
12. In the Write Policy dialog box, select the option Always Write Back, then press Enter.
13. In the next dialog box, select the option Select Drives, then press Enter.

Table of Contents

Other manuals for Bosch DIVAR IP all-in-one 6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch DIVAR IP all-in-one 6000 and is the answer not in the manual?

Bosch DIVAR IP all-in-one 6000 Specifications

General IconGeneral
BrandBosch
ModelDIVAR IP all-in-one 6000
CategoryNetwork Hardware
LanguageEnglish

Related product manuals