Easy Series (ICP-EZM2) | Installer Guide | 2.0 Installation
12 Bosch Security Systems, Inc. | 5/07 | F01U025147-01
2.4 DX2010 Installation (Step 4)
The control panel supports up to three DX2010 Input Expanders for Points 9 to 32.
Refer to the DX2010 Installation Instructions (P/N: 49533) for more information.
1. Mount the DX2010 into the
control panel’s enclosure, or other
suitable enclosure.
=
2. Set the DX2010’s DIP switches.
- Points 9 to 16 = Address 102
- Points 17 to 24 = Address 103
- Points 25 to 32 = Address 104
102
103
104
3. Connect the DX2010 to the
control panel.
Connect a wire jumper to the
TMPR and COM terminals to
disable the DX2010’s tamper
input.
For point wiring options, refer to
Section 2.6 Supervised Point
Connections on page 14.
+OUT- TMPR 1 COMR B G Y
R
B
G
Y
ON
OFF