Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
52 Bosch Security Systems, Inc. | 5/07 | F01U025147-01
4.3.7 Control Center Programming Items
Speech Configuration Items
Programming Item
Item
Number
Description (Range) Entry
Alarm Message
Minimum Repeat Time
880
Enter how long the control center waits between alarm message
announcements before repeating the message even if the control
center’s proximity sensor detects motion (1 to 255 hrs).
12
“No Alarm Report
Sent” Announcement
883
0 = No announcement for aborted alarms.
1 = Control center announces “No alarm report sent” for aborted
alarms.
1
“Cancel Report Sent”
Announcement
884
0 = No announcement for canceled alarms.
1 = Control center announces “Cancel report sent” for cancelled
alarms.
1
Time Format
887
0 = Determined by voice module
1 = Always use 12-hr mode
2 = Always use 24-hr mode
0
Global Control Center Items
These programming items affect all control centers connected to the control panel.
To send a user fire, emergency (medical) or panic report, the appropriate control center button and report
must be enabled. Refer to Section 4.3.4 Report Routing Programming Items on page 43 to enable reports.
Check the appropriate box in the Easy Series User Guide (P/N: F01U025111) to identify which buttons are
enabled.
Programming Item
Item
Number
Description (Range) Entry
Fire Button Alarm
888
0 = Item disabled.
1 = Press and hold [1] for 2 sec to start a fire alarm.
0
Medical Button Alarm
889
0 = Item disabled.
1 = Press and hold [1] and [2] for 2 sec to start a medical alarm.
System announces medical alarm message once every minute
for five min.
0
Panic Button Alarm
890
0 = Item disabled.
1 = Press and hold [2] for 2 sec to start an audible panic alarm.
2 = Press and hold [2] for 2 sec to start a silent panic alarm.
0
One Button Arming
891
0 = Token or passcode is required to turn the system on.
1 = Press [i] to start Exit Delay for the first available system-on
option. No token or passcode is needed.
0
Invalid Passcode
Attempt Limit
892
Enter the number of times a user can enter an invalid passcode, or
present an invalid token, before the user is locked out (3 to 8).
3
Control Center
Lockout Time
893
Enter the number of minutes that a user is locked out when the
Invalid Passcode Attempt Limit is reached (1 to 30).
3