Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01 31
4.2.1 Points
You cannot program any wireless points without first completing the steps in Section 1.4 System
Setup on page 5.
Points
Enter a point number from 1 to 32.
1 Record Point Description
For example, if Point 1 is located at the building’s front door, say “Front Door” at the tone.
Press [1] to continue programming the selected point.
Press [2] to re-record your current point description.
2 Set Point Type
Press [1] to select the current option.
Press [2] to hear more options.
Press [#] to exit Point Type.
Point Type Description
Disabled Point is disabled.
Perimeter
(Entry or Exit)*
If faulted and the system is on, Entry Delay starts. An alarm occurs if the system is
not turned off when Entry Delay ends.
Interior (Follower)*
If the system is on occupied, it ignores these points. If the system is on
unoccupied, a faulted interior point starts an alarm. These points are ignored
during Exit and Entry Delay times.
Perimeter Instant* If faulted when the system is on, a local alarm occurs.
24-Hour
If faulted, an alarm always occurs. To restore a 24-hour point, turn the system off if
it is on, or acknowledge the alarm if the system is off.
Fire Verified
If faulted, fire verification occurs. If a second fire event occurs during the two-min.
wait period, a fire alarm occurs. If no second fire event occurs, the system returns
to normal.
Fire Instant If faulted, a fire alarm always occurs.
Silent Panic
If faulted, an alarm always occurs. There is no visual or audio indication of the
alarm.
Interior Walkthrough*
If faulted and the system is on custom protection, Entry Delay starts. If the system
is on occupied or unoccupied, this point functions as an interior point.
Perimeter Exit
Cancel*
If faulted and restored during Exit Delay, Exit Delay stops and the system
immediately turns on.
Momentary Keyswitch Turn the system on or off using a momentary keyswitch.
Maintained Keyswitch Turn the system on or off using a maintained keyswitch.
# Exit Points
Return to the Installer Menu.
* An alarm report is not sent to the central station if the system is turned off within the abort window.
Record point programming entries in the Point Programming Entry Tables starting on page 47.