7.7.6 EN50131-1
The Easy Series Intrusion Control Panel is designed to comply with EN50131-1 Security Grade 2,
Environmental Class II.
Installation, Programming, and Maintenance
Installation: Refer to Section 2.0 Installation on page 8.
Programming: Refer to Section 4.0 Programming on page 29.
Testing: Refer to Section 5.0 System Test on page 56.
Maintenance: Refer to Section 6.0 Maintenance on page 56.
Power Supply (AC and Standby Battery)
AC Power Supply: Refer to EZPS Power Supply Requirements on page 75.
Standby Battery: Refer to Control Panel Power Requirements on page 75.
Automatic Inhibit
Intruder Alarm and Fault Signal or Message: Set Expert Programming Item Number 131 to a value
between 1 and 3.
Refer to page 39 for more information.
Authorization Code: Set Expert Programming Item Number 892 to a value between 3 and 8.
Refer to page 52 for more information.
Logical and Physical Keys
Minimum Number of Combinations per User:
- Passcodes: 15,625 (passcode length must be six digits)
- Tokens: 42,000,000,000
- Key Fobs: 2,800,000,000,000,000
Method Used to Determine Number of Combinations:
- Passcodes: Digits 1 to 5 are allowed. For a six-digit passcode, all combinations are allowed.
- Tokens: 32 bits. All combinations are allowed.
- Key Fobs: 56 bits (48 serialized during manufacturing, 8 remain static)
Operating Temperature Range
Refer to Environmental Considerations on page 74.
Control Panel and Control Center Current Consumption
Control Panel: Refer to Control Panel Power Requirements on page 75.
Control Center: Refer to Control Center on page 74.
Output Current Rating
Refer to Programmable Outputs on page 74.
To comply with EN50131-1, set these programming items as follows:
Programming Item Item Number Setting Page Reference
Entry Delay 127 Set to 45 sec or less 38
Swinger Bypass Count 131 Select Option 3 39
Restrict Installer Passcode 142 Select Option 1 39
Passcode Length 861 Set passcode length to six digits 53