Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01 51
4.3.6 Output Programming Items
Use Outputs 5 to 8 only for wireless output devices.
Programming Item
Item
Number
Description Entry
Fire Output Cadence
600
0 = Temporal Code 3 cadence
1 = Pulse cadence
(two-sec on, two-sec off)
0
Output 1 Type
611
5
Output 2 Type
621
5
Output 3 Type
631
7
Output 4 Type
Supervised speaker driver
option. Refer to Expert
Programming Item Number
642.
641
5
Output 5 Type (wireless)
651
0
Output 6 Type (wireless)
661
0
Output 7 Type (wireless)
671
0
Output 8 Type (wireless)
681
Refer to Section 4.2.3 Outputs on page 33 for output function
descriptions.
0 = Output disabled 7 = System Reset
1 = Intrusion 8 = System On
2 = Intrusion Latching 9 = System Ready
3 = Fire 10 = Key Fob On/Off
4 = Fire Latching 11 = Key Fob 2-sec Pulse
5 = Intrusion and Fire 13 = User Controlled
6 = Intrusion and Fire Latching
0
Output 4 Function
642
0 = Supervised 8 Ω speaker driver
1 = Unsupervised open collector
(voltage level)
0
Default
= Country-specific default. Select this programming item to hear the updated default value.
When programming a wireless output (for example, a siren or relay module), do not select an
output function that requires the output to activate for an extended period (for example System
Ready).