Easy Series (ICP-EZM2) | Installer Guide | 7.0 Reference Materials
60 Bosch Security Systems, Inc. | 5/07 | F01U025147-01
7.4 Event Report Codes
Event SIA Report Contact ID Report
Intrusion Alarm BA Burglary Alarm 1 130 Burglary
Intrusion Alarm Verified BV Burglary Alarm Verified 1 139 Burglary
Intrusion Alarm Unverified BG Unverified Event Burglary 1 130 Burglary
Intrusion Alarm 24-hr BA Burglary Alarm 1 133 24 Hour (Safe)
Intrusion Alarm 24-hr Restoral BH Burglary Alarm Restore 3 133 Restoral
Intrusion Alarm Restoral BR Burglary Restoral 3 130 Burglary
Duress HA Hold Up Alarm 1 121 Duress
Exit Error EA Exit Alarm 1 374 Exit Error (zone)
Fire Alarm FA Fire Alarm 1 110 Fire
Fire Alarm Unverified FG Unverified Event-Fire 1 110 Fire
Fire Alarm Restoral FH Fire Alarm Restore 3 110 Fire
Panic HA Holdup Alarm 1 120 Panic
Panic Restoral HH Holdup Alarm Restore 3 120 Panic
User Emergency (Medical) QA Emergency Alarm 1 101 Personal Emergency
User Fire FA Fire Alarm 1 110 Fire
User Fire Restoral FH Fire Alarm Restore 3 110 Fire
User Panic HA Holdup Alarm 1 120 Panic
Cancel BC Burglary Cancel 1 406 Cancel
Intrusion Trouble BT Burglary Trouble 1 380 Sensor Trouble
Intrusion Trouble Restoral BJ Burglary Trouble Restore 3 380 Sensor Trouble
Intrusion Point Bypass BB Burglary Bypass 1 570 Zone/Sensor bypass
Intrusion Point Bypass Restoral BU Burglary Unbypass 3 570 Zone/Sensor bypass
Fire Trouble FT Fire Trouble 1 373 Fire Trouble
Fire Trouble Restoral FJ Fire Trouble Restore 3 373 Fire Trouble
Recent Closing CR Recent Closing 1 459 Recent Closing
Close (System On) Unoccupied CL Closing Report 3 401 Unoccupied Arm by User
Close (System On) Occupied CL Closing Report 3 441 Occupied Arm by User
Close (System On) Custom CL Closing Report 3 441 Custom Arm by User
Close (System On) Partial CL Closing Report 3 456 Partial Arm by User
Close (System On) Keyswitch CS Closing Keyswitch (User 255) 3 409 Keyswitch O/C (User 255)
Open (System Off) OP Opening Report 1 401 O/C by User
Open (System Off) Keyswitch OS Opening Keyswitch (User 255) 1 409 Keyswitch O/C (User 255)
AC Fail AT AC Trouble 1 301 AC Loss
AC Fail Restoral AR AC Restoral 3 301 AC Loss
Auto System Test (Normal) RP Automatic Test 1 602 Period Test Report (User 0)
Auto System Test (Off-Normal) RY Test Off Normal 1 608 Period Test Report, System Trouble
Present
Auxiliary Power Fault IA Equipment Failure Condition 1 310 Ground Fault
Auxiliary Power Restoral IR Equipment Fail Restoral 3 310 Ground Fault
Communication Fail YC Communications Fail 1 354 Failure to communicate event
Communication Restoral YK Communications Restoral 3 354 Failure to communicate event
Control Center Supervision Fail EM Expansion Device Missing 1 333 Expansion module failure
Control Center Supervision Restoral EN Expansion Missing Restore 3 333 Sensor Trouble
Control Center Tamper ES Expansion Device Tamper 1 341 Expansion Device Tamper
Control Center Tamper Restoral
EJ Expansion Device Tamper
Restore
3 341 Expansion Device Tamper
Local Programming LX Local Programming Ended 1 628 Program mode exit
Low Battery YT System Battery Trouble 1 302 Low System Battery
Low Battery Restoral YR System Battery Restoral 3 302 Low System Battery
Communication Test RX Manual Test 1 601 Manual trigger test report
Phone Line Fault LT Phone Line Trouble 1 351 Telco 1 fault
Phone Line Fault Restoral LR Phone Line Restoral 3 351 Telco 1 fault