Easy Series (ICP-EZM2) | Installer Guide | 7.0 Reference Materials
.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01 61
Event SIA Report Contact ID Report
ROM Fault YF Parameter Checksum Fail 1 304 ROM Checksum Bad
Bell Trouble YA Bell Fault 1 320 Sounder/ Relay
Bell Restoral YH Bell Restored 3 320 Sounder/ Relay
Walk Test End TE Test End 3 607 Walk Test Mode
Walk Test Start TS Test Start 1 607 Walk Test Mode
Bus Device Missing EM Expansion Device Missing 1 333 Exp. Module Failure
Bus Device Missing Restoral EN Expansion Missing Restore 3 333 Exp. Module Failure
Battery Missing YM System Battery Missing 1 311 Battery Missing/Dead
Battery Missing Restoral YR System Battery Restoral 3 311 Battery Missing/Dead
RAM Checksum Failed YF Parameter Checksum Fail 1 303 RAM Checksum bad
Point Tamper TA Tamper Alarm 1 137 Tamper
Point Tamper Restoral TH Tamper Alarm Restoral 3 137 Tamper Restoral
Cross Zone Trouble BG Unverified Event - Burglary 1 378 Cross-zone Trouble
Cross Zone Trouble Restoral BR Burglary Restoral 3 378 Cross-zone Trouble
Point Missing UY Untyped Missing Trouble 1 381 Loss of Supervision – RF
Point Missing Restoral UJ Untyped Trouble Restore 3 381 Loss of Supervision – RF
Wireless Point Low Battery XT Transmitter Battery Trouble 1 384 RF Low Battery
Wireless Point Low Battery Restoral XR Transmitter Battery Restoral 3 384 RF Low Battery
Wireless Receiver Jammed XQ RF Interference 1 344 RF Receiver Jam Detect
Wireless Receiver Jammed Restoral XH RF Interference Restoral 3 344 RF Receiver Jam Detect
Bus Device Tamper XS RF Receiver Tamper 1 341 Exp Module Tamper
Bus Device Tamper Restoral XJ RF Receiver Tamper Restoral 3 341 Exp Module Tamper
Bus Device Trouble ET Expansion Trouble 1 330 System Peripheral Trouble
Bus Device Trouble Restoral ER Expansion Restoral 3 330 System Peripheral Trouble
Remote Programming Success RS Remote Program Success 1 628 Program mode exit
Remote Programming Failure RU Remote Program Fail 1 628 Program mode exit
The following table shows:
Non-standard event messages that appear in the history log, and
Event messages for SMS Text and Voice formats
Event History Log Entry SMS Text Format Voice Format
Tamper Enclosure Tamper 0 Point Trouble 0 Tamper 0
Duress Duress; System Off User 22 Intrusion Alarm System Off Duress System Off User 22
Quick Arm
System On Occupied User 0
System On Unoccupied User 0
System On Custom User 0
System On User 0
System On Occupied User 0
System On Unoccupied User 0
System On Custom User 0
Keyswitch On System On Unoccupied 255 System On User 255 System On Unoccupied 255
Keyswitch Off System Off 255 System Off User 255 System Off 255
Recent Close Recent Close User X Intrusion Alarm Recent Close User X