Easy Series (ICP-EZM2) | Installer Guide | 2.0 Installation
.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01 21
2.11.2 Plug-in Power Supply
1. Connect a ground wire from the enclosure to a good
earth ground source.
2. Connect the enclosure ground wire.
For instructions, refer to Steps 5 to 8 in Section 2.11.1
EZPS Wire-in Power Supply on page 19.
3. Connect the plug-in power supply to the control panel
board.
2
1
3
2.11.3 12 VDC Standby Battery
When all system wiring is complete, apply AC and standby
battery power to the control panel.
(+)
(-)
12 VDC