Easy Series (ICP-EZM2) | Installer Guide | 2.0 Installation
16 Bosch Security Systems, Inc. | 5/07 | F01U025147-01
2.7 Programmable Output Connections (Step 7)
Separate primary AC power and standby battery wires from all power-limited wiring. Refer to
Section 7.2 Power-limited Wire Routing on page 58 for more information.
2.7.1 Programmable Output 1 Wiring
Switched 12 V Option
(+) (-)
2
3
1
(+)
+
-
(-)
2
1
3
4
5
Warning device (without battery)
1 - Programmable Output 1 (PO 1)
2 - Jumper plug position for switched 12 V option
3 - Warning device
Warning device (with battery)
1 - Programmable Output 1 (PO 1)
2 - Jumper plug position for switched 12 V option
3 - Control panel board white auxiliary power
terminals (12 VDC)
4 - Warning device
5 - Warning device activates when trigger voltage
is removed
Switched Ground Position
(-)(+)
2
4
3
1
1 - Programmable Output 1 (PO 1)
2 - Jumper plug position for switched ground option
3 - Control panel board white auxiliary power terminals (12 VDC)
4 - Warning device