Easy Series (ICP-EZM2) | Installer Guide | 7.0 Reference Materials
.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01 73
7.7.7 PD6662 and DD243 Requirements
To comply with PD6662 and DD243, you must meet all of the EN50131-3 requirements and the following
requirements:
Maintenance
A qualified technician must check the system at least twice a year.
AC Power Supply
• Type: A
• Rated Voltage: 230 V
• Rated Input Frequency: 50 Hz
• Rated Input Current: 250 mA maximum
• Fuse Rating: 0.25 A, 250 V Slow Blow
Construction Material
Enclosures and housings for the control panel, control center, DX2010, wireless hub, and wireless devices are made from
materials that are durable, secure, and resistant to attack by hand-held tools.
Confirmed Alarms
Set Expert Programming Item Number 124 to either Option 3 or 4. Refer to page 38 for more information.
The Easy Series Intrusion Control Panel is designed to comply with PD6662:2004 as a Grade 2 system that
supports Notification Options A, B, C, or X with the appropriate notification devices installed (devices not
included with system).
7.7.8 INCERT
To comply with INCERT, set these programming items as follows:
Programming Item Item Number Default Page Reference
Restrict Installer Passcode 142 1 39
Passcode Length 861 6 digits 53
Invalid Passcode Attempt 892 3* 52
Control Center Lockout Time 893 3* 52
* To comply with INCERT, set these programming items to 3 or higher.
7.7.9 cUL
For Canadian installations, install systems according to ULC-S302. Systems that use the C900V2 Conettix IP
Dialer Capture Module meet Level 3 Line Security when communicating over a packet-switched data network
(PSDN).