A.4 List of criteria
Criterion Number Alarm (A)
or Event (E)
Sent to DECT/
Paging systems
Comment
ERROR 00 A Yes System malfunction, e.g. component defective
PERSONNEL A 01 E No Coded key active (N46)
LOW BATTERY 02 A Yes Battery at low level (Transmitter)
ACK. N46 03 E No Acknowledgement (Sent by N46, S35 or S37)
DOOR 04 E No Door open or door closed
TECHNICAL 05 A Yes Technical Call (N46)
PERSONNEL C 06 E No Coded key presence (N46)
HELP 07 A Yes Call for Help
UNKNOWN 08 E No Not used
END PERSONNEL 09 E No Removed coded key (N46)
PERSONNEL D 10 E No Coded key presence (N46)
ASSISTANCE 11 A Yes Assistance Call
24 HOURS 12 E No Daily message check
RESERVE 13 A Yes Reserve Call (N46)
PERSONNEL B 14 E No Coded key presence (N46)
RADIO NOISE 15 E No Bad radio transmission (noise)
FIRE 16 A Yes Fire Alarm
ACK. TRANSM.1 17 E No Acknowledgement (Ack. Transmitter No. 1)
LOCAL ACK. 18 E No Local Acknowledgement (Main Unit or Relay Unit)
POWER OUTAGE 19 E No Main Unit or Relay Unit not powered
POWER BACK 20 E No Power back (Main Unit or Relay Unit)
COMPUTER OFF 21 E No Alarm management PC off
COMPUTER ON 22 E No Alarm management PC on
BAT.ACK.TRANSM 23 E No Battery at low level (One of the Ack. Transmitter)
RELAY ON 24 E No Relay Unit connected on RS-485 Bus
RELAY OFF 25 A No Relay Unit disconnected from RS-485 Bus
NO RELAY 26 E No Relay Unit off acknowledged (Main Unit)
LOW ACCU 27 E No Accumulator discharged (Main Unit or Relay Unit)
ACK. TRANSM.2 28 E No Acknowledgement (Ack. Transmitter No. 2)
ACK. TRANSM.3 29 E No Acknowledgement (Ack. Transmitter No. 3)
ACK. TRANSM.4 30 E No Acknowledgement (Ack. Transmitter No. 4)
ACK. TRANSM.5 31 E No Acknowledgement (Ack. Transmitter No. 5)
ACK. TRANSM.xx xx E No Acknowledgement (Ack. Transmitter No. xx)
ACK. TRANSM.32 58 E No Acknowledgement (Ack. Transmitter No. 32)
DEMENTIA 60 A Yes Dementia Alarm
NOTICE!
All events are buffered into the event buffer of the NurseCall Main Unit. All alarms and events
are sent to the printer. All alarms and events except the events "COMPUTER OFF" and
"COMPUTER ON" are sent to the Alarm management Software.