NurseCall Main Unit | en 57
Bosch Security Systems User Manual F.01U.252.699 | V1.1 | 2012.01
The x digit can be programmed. See Section Specific parameter for DeTeWe, page 30.
Change day / night
The DeTeWe protocol does not handle the day / night transfer.
Priority alarms
The assistance and fire alarms are priority calls sent to all activated pagers.
A.5.4 Medicall 800 protocol
Characteristics
– Data rate: 9600 Bauds
– Transmission: asynchronous
– 10 bit-structure (1 start bit, 8 data bits, no parity, 1 stop bit)
– Half-duplex mode.
Only alarms arriving to the alarm buffer are transmitted (except "Relay Off").
Acknowledgement messages are also transmitted. Each alarm is sent only with the pager
group information corresponding to the transmitter that has sent the alarm. This is performed
without any criterion distinction.
Change day / night
The Medicall 800 protocol does not handle the day / night transfer.
Call repetition
If alarms or messages are not acknowledged after approximately 3 minutes, call repetitions
are issued.
09 x09
10 x10
11 x11
12 x12
13 x13
14 x14
15 x15
16 x16
17 x17
18 x18
19 x19
20 x20
21 x21
22 x22
23 x23
24 x24
Group User number