Clause / Requirement Compliance Signature
The marking shall be such that it shall be
possible to adjust the user controls and to
confirm their positions accurately in
conformity with the information given in
the user instructions.
Compliant.
Marking shall preferably include letter
symbols, signs, numbers and colors that
are internationally comprehensible.
Reference is required to IEC60027 and
IEC60417. Marking not included in these
standards shall be clearly explained in the
user instructions.
Compliant.
5.9 Electrical matching values
For the electrical matching values,
reference is required to IEC61938 unless
otherwise specified.
Compliant (specified in Technical
data sections).
5.10 Connectors
Connectors shall comply with IEC60268-11
or IEC60268-12. Requirements for fire
resistance of connectors may also be
stipulated by the relevant authorities.
Connectors comply to
IEC60268-11 or IEC60268-12.
Additional requirements are the
responsibility of the installer, i.e.
cables wiring and loudspeakers
should comply with IEC60849.
Responsibility of the installer..
6. Installation requirements
Clause / Requirement
Compliance Signature
The system shall be installed in accordance
with IEC60364 or with mandatory national
or local standards.
Responsibility of the installer.
If the emergency sound system forms part
of an emergency detection and/or alarm
system, the cabling shall meet the
requirements of mandatory national or
local, emergency and/or alarm system
standards. Where the application
specifically excludes detection and/or
alarm, the cabling shall be of a standard
suitable for the application.
Responsibility of the installer.
Precautions shall be taken to prevent the
spread of hazardous effects via the wiring
routes.
Responsibility of the installer.