Power
Introduction
The voice alarm controller has the following power connections:
– Mains power connection.
– Back-up power connection.
Mains power
Proceed as follows to connect the voice alarm controller to the mains power:
4 Select the local mains voltage using the voltage selector on the rear of the voice alarm
controller.
Figure 5.16: Voltage selector
Selector
Mains voltage V(AC) Fuse
115 100 - 120 115 V - 10 AT
230 220 - 240 230 V - 6,3 AT
Table 5.3: Voltage selector
Notice!
The Voice Alarm Controller is delivered with the voltage selector in the 230 V position.
1. Put the correct type of fuse in the voice alarm controller.
Notice!
The Voice Alarm Controller is delivered with a T6.3L 250 V fuse for a mains voltage of
220 to 240 V(AC).
2. Connect a locally approved mains cord to the voice alarm controller.
3. Connect the mains cord to a locally approved mains outlet.