Remote control
With the Voice Alarm Remote Control, it is possible to control the voice alarm controller from
another site. The remote control is also available as kit (Voice Alarm Remote Control Kit) for
creating customized solutions. The maximum number of remote controls that can be
connected to the voice alarm controller is 2. A special type of remote control is the Fireman’s
Panel.
Controls, connectors and indicators
0
-
+
-
+
0 dB
-6dB
-20dB
Processor reset
Network
Call/EMG
Music/Spare
Ground short
Input
Mains
Battery
Zone1
Zone2
Zone3
Zone4
Zone5
Zone6
Alarm
Zone select
Plena Voice Alarm C
ontroller
Fault Indicators
CD/Tuner
Aux
Select
Zone select
Indicator test
EMG mic
Alert message
Alarm message
All call
Zone1 Zone2 Zone3 Zone4 Zone5 Zone6
Fault
EMG
Ack
Reset
A
B
Disabled
Message
EMG mic
RCP
Router
CO M
NC
NO
10k
10k
Trigger input/24V DC out
Business
Emergency
NC
TRG2
Override/Trigger Output
AUX
L
R
PC
Digital
Mess age
Monitoring
Speaker
Remote Control Panel
Impedance
Calibration
In
LBB 1 990 /00 8900 199 0 0 001
Plena Voice Alarm Controller
Max. output power 360W
Rated output power 240W
115-230V~, 50/60Hz
S/N.
Design & Quality
The Netherlands
N663
Phantom power
Z1
Z2
Z3
Z4
Z5
Z6
Ext
B ooster
In
DC In
100V
0
TRG 1
Int
B ooster
Out
24V
EM G
Fault
C all
External Booster
Out
CD/Tuner
SEL1
SEL0
Firmware
Upgrade
Monitor
APR mode
Supervision
2ch operation
Reserved
Off
On
USB
Vox
Speech filter
Mic/Line
Vox
Reserved
Rated input power:760VA
Line fuse
T6.3L250V for230V AC
T10L250V for115V AC
115V~
230V~
Apparatus delivered
C onnected for 230V~
Power
Router
W arning
This apparatus must be earthed
100V
0
100V
0
100V
0
100V
0
100V
0
100V
0
24V
70 V
Z1
Z2
Z3
Z4
Z5
Z6
GND
Reserved
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
Off
On
Off
On
Call station
For ser vice only
GND
24V
DC out
VOX
Switch
VOX Switch
1 2 3 4 5 6
NC
COM
NO
NC
COM
NO
NC
COM
NO
100V
0
C all out
100V
0
100V
0
100V
0
100V
0
100V
0
100V
0
Z2
Z3
Z4
Z5
Z6
Z1
A B
NO
24V
DC out
24V
1 Channel
2 Channel
Int Booster
Ext Booster
BGM /Spare
N.C ./Spare
Call
BGM / C all
Volume Override
100 V
Made in China
1
2
1
2
EMG. Mic
1
2 3 4 5
6712151617
32333435363739
1013
89
384041424647
18 19 20 22 23 24 25 26 27 28 30 312921
4445 43
1114
Figure 3.2: Front and rear views of the voice alarm controller
Controls, connectors and indicators on the voice alarm controller:
1. Power LED/VU Meter:
A combined power indicator and VU meter. The green power LED is lit if the voice alarm
controller is connected to the mains or back-up power and switched on. The VU meter
indicates the master VU level: 0 dB (red), 6 dB, -20 dB (yellow).
Notice: As the pilot-tone level of the VAS is -20 dB or -23 dB in some amplifiers, the -20
dB LED will be on continuously. This is normal.