External power amplifier
The voice alarm controller has 1 external power amplifier output (line level, 1 V) and 1 external
power amplifier input (100 V) to connect an external power amplifier. The function of the
external power amplifier (e.g. a Plena Power Amplifier 360/240W) depends on the channel
mode for which the voice alarm controller is configured (see section 1-Channel mode
operation, page 77 and section 2-Channel mode operation, page 78).
100V 70V 0 0
line in line out
1 2
3
1 2
3
GND GND+ +
- -
CO M
NC
TRG2
Z2
Z3
Z4
Z5
Z6
Ext
Booster
In
DC In
0
TRG 1
Int
Booster
Out
24V
Fault
Call
External Booster
Out
100V
0
100V
0
100V
0
100V
0
100V
0
100V
0
24V
70V
Z2
Z3
Z4
Z5
Z6
GND
NC
COM
NO
NC
COM
NO
NO
100V
0
Call out
0
100V
0
100V
0
100V
0
100V
0
100V
0
Z2
Z3
Z4
Z5
Z6
NO
Volume Override
100V
Figure 5.4: Connecting an external power amplifier
5.1.4
52 en | Connection Plena