Figure 6.7: Call station DIP switches
DIP switch
Description
1, 2, 3, 4 Set the ID of the call station. See section Call station ID, page 83.
5, 6 Set the sensitivity of the call station. See section Sensitivity, page 83.
7 Switches the speech filter on (ON) and off (OFF). See section Speech filter,
page 84.
8 Switches termination on (ON) and off (OFF). See section Termination, page
84.
Table 6.7: Call station DIP switches
Call station ID
The ID of the call station is set using switches 1 to 4. Each call station must have a unique ID
(1 to 9).
Sensitivity
The sensitivity of the call station is set using switches 5 and 6:
Sensitivity Switch 5 Switch 6
-15 dB OFF OFF
0 dB OFF ON
6 dB ON OFF
Reserved ON ON
Table 6.8: Call station sensitivity
6.4
6.4.1
6.4.2
Plena Configuration | en 83
Bosch Security Systems B.V. Installation and Operation manual 2013.07 | V2.0 |