REFUspeed RS51 Electrical installation 5-19
DOK-RD500*-RS51*******-IB02-EN-P
5.9 Standard SS6 interface (X13)
Note: Only for internal use.
5.10 Standard terminal assignment of the REFU
speed
RS51
Recommended terminal assignment with good compatibility to the
REFU 316F
For this recommended assignment, a KL17037 must be inserted at option
slot 2.
Note: This means, that there is only 1 option slot available for other
modules!
REFUspeed RS51 REFU 316 F Function
Terminal Designation Module Terminal Module
X11 SR17000 X16 IO4004 Operator panel
X11 SR17000 - - RS232 service interface
- - X21 RS4012 RS232 interface
X12 SR17000 - - RS485 interface
X14.1 SR17000 X2.32 Terminal 24V / 50mA control voltage output
X14.7 SR17000 X2. 0V digital reference point
X17.1 SR17000 X2.11 Terminal 15V / 50mA control voltage output
X17.8 SR17000 X2.48 Terminal 0V digital reference point
X14.2 Dig In/Out 1 SR17000 X56.11/1
2
WM4034 Dig. output for WM signal
“Sparking” signal
or signal “Load limit”
X14.3 Dig In/Out 2 SR17000 Motpot. active load monitor sensitivity up /
(can be freely configured)
X14.4 Dig In/Out 3 SR17000 Motpot. active load monitor sensitivity down
/ (can be freely configured)
X14.5 Dig In 4 SR17000 X2.10 Terminal
Par. set selection, weighting 2
4
X14.6 Dig In 5 SR17000 X2.9 Terminal External fault acknowledgement
X17.2 Dig In 6 SR17000 X2.33 Terminal Start NO contact
X17.3 Dig In 9 SR17000 X2.13 Terminal
Par. set selection, weighting 2
1
X17.4 Dig In 7 SR17000 X2.31 Terminal Stop NC contact
X17.5 Dig In 10 SR17000 X2.14 Terminal
Par. set selection, weighting 2
2
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01