REFUspeed RS51 Basic parameterization 7-21
DOK-RD500*-RS51*******-IB02-EN-P
Drive setting
Parame-
ter No.:
Name Description / explanation
selectable options
Factory setting
min ... max values
Pass
wor
d
0071 Load factorySetting
0 = no action
1 = basic, standard values are loaded
Parameters, with a password level less than
or the same as the entered password level
are set to the standard value of the basic
parameterization.
P0064 0 = Basic parametrization
P0057 0 = not active
2 = free standard values are loaded
Parameters with a password level less than
or equal to the entered password level are set
to the standard value of the free parameter
ization.
P0064 1 = Free parametrization
P0057 0 = not active
3 = standard values for NAMUR applications are
loaded
Parameters, with a password level less than
or the same as the entered password level
are set to the standard value of the basic
parameterization with activated NAMUR func
tions.
P0064 0 = Basic parametrization
P0057 1 = active
4 = standard values for Sercos applications are
loaded
Parameters, with a password level less than
or the same as the entered password level
are set to the standard value of the free
parameterization for Sercos applications.
P0064 1 = Free parametrization
P0057 0 = not active
The parameters with are relevant for
applications with Sercos option interface are
set.
No action
0 ... 4
0
0732 Copy from keypad Caution: Only those parameters are copied which are
enabled as a result of the selected password.
The data set, saved in the operator panel is copied
into the drive.
0= no
1= yes
2 = designation (the saved data set designation
canbeviewedhere)
No
0 ... 2
0733 Copy data to keypad The complete drive converter data set is copied into
the operator panel.
0= no
1= yes
A data set name can be entered after the data trans-
fer.
You can scroll through the ASCII code using the + and
- keys (the system goes to the start of the following
ranges by simultaneously pressing the + and - keys: A,
a, 0 and the blank symbol).
You can move the cursor to the right or left using the <
or > key.
No
0/1
0
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Rexroth REFUspeed RS51 and is the answer not in the manual?

Bosch Rexroth REFUspeed RS51 Specifications

General IconGeneral
BrandBosch
ModelRexroth REFUspeed RS51
CategoryController
LanguageEnglish

Related product manuals