EasyManua.ls Logo

Bosch Rexroth REFUspeed RS51 - Guided Parameterization; Drive Control; Setpoints

Bosch Rexroth REFUspeed RS51
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-6 Basic parameterization REFUspeed RS51
DOK-RD500*-RS51*******-IB02-EN-P
t
0 %
-100%
100%
Setpoint
RFG output
Ramp-up
time
Ramp-
down
time
Direction of
rotation reversal
Ramp-up
time
Ramp-
down
time
Fig. 7-3: Up and down ramps
7.4 Guided parameterization
Drive control / setpoints
Pa-
rameter
No.:
Name Description / explanation
selectable options
Factory setting
min ... max values
Pass
wor
d
0870 On/off for NORMAL
Enters On/off for NORMAL operation
0 = Term. steady-st. (steady-st.
corr. to a switch function)
1 = T. stat.+OP(T=terminals
OP=operator panel)
2 = T. stat.+PC (PC w/ RE
FUwin via service-
interface)
3 = T. stat.+bus SS1
(SS = serial interface)
4 = T. stat.+bus SS2 (if
available)
5 = T. stat.+bus SS4 (if
available)
6 = T. dyn. (OFF always)
(dyn.=dynamic)
7 = OP dyn. (OFF always)
8 = T. dynamic (dynamic
corr. to a pushbutton funct.)
9 = OP dynamic
10 = OP static
11 = T. stat.+bus SS6
Terminal dynamic
0...11
1
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01