REFUspeed RS51 Basic parameterization 7-9
DOK-RD500*-RS51*******-IB02-EN-P
Standard terminal assignment
Parame-
ter No.:
Name Description / explanation
selectable options
Factory setting
min ... max values
Pass
wor
d
0875 Dig. input, output1
Combined digital input and output
0=I no function (I=input)
2=I no alarm ext. (alarm)
3=I no fault ext. (fault)
4=I fault reset
5=I fmin select
6=I direct. rotat. (direction of
rotation reversal)
7=I no volt. disc. (power
disconnected)
8=I no fast stop (fast stop)
9=I RFG park (RFG=ramp-funct.gener.)
10 = I RFG-up stop
11 = I motp. faster
(motp.=motorized potentiometer)
12 = I motp. slower
13 = I ALM sensitivity up
14 = I ALM sensitivity down
15 = I ALM autom. sensitivity adjust.
start/stop
16 = I ALM inhibit, sparking
17 = I ALM inhibit, load limit
20 = I setp. mem. bit4 (weighting 2
4
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
21 = I TEST/STANDARD (toggles between
the TEST and STANDARD modes,
simultaneously disables the
changeover from the operator
panel.)
22 = I setp. mem. bit0 (weighting 2
0
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
23 = I setp. mem. bit1 (weighting 2
1
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
24 = I setp. mem. bit2 (weighting 2
2
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
25 = I setp. mem. bit3 (weighting 2
3
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
26 = I parblock bit0 (weighting 2
0
:
Changes-over the specific motor
data
27 = I parblock bit1 (weighting 2
1
:
Changes-over the specific motor
data
28 = I parblock bit2 (weighting 2
2
:
Changes-over the specific motor
data
O ALM
sparking signal
0...97
1