7-12 Basic parameterization REFUspeed RS51
DOK-RD500*-RS51*******-IB02-EN-P
Parame-
ter No.:
Name Description / explanation
selectable options
Factory setting
min ... max values
Pass
wor
d
0762 Time, timer Supplementary parameter for “setpoint in the tolerance
bandwidth”.
1.0 sec 2
Time for the timer 0.0 ... 650.0 sec
1206 ALM sparking Supplementary parameter for “O ALM sparking signal” Inverted 2
0=direct
1=inverted
0...1
1220 ALM load limit Supplementary parameter for “O ALM load limit” Inverted 2
0=direct
1=inverted
0...1
0876 Dig. in-, output2
I WLM sensitivity
up
1
As for parameter 0875 0...97
0463 Mode dig. output Supplementary parameter for P0876 for all output
functions
Output, direct 1
0 = output direct
1 = output inverted
0...1
0877 Dig. in-, output3
I WLM sensitivity
down
1
As for parameter 0875 0...97
0465 Mode dig. output Supplementary parameter for P0877 for all output
functions
Output, direct 1
0 = output direct
1 = output inverted
0...1
0878 Digital input4
I parset bit4
1
As for parameter 0875, from value 0 bis 69. 0...67
0879 Digital input5 Fault acknow-
ledgement
1
As for parameter 0875, from value 0 to 69. 0...67
0880 Digital input8
I parset bit0
1
As for parameter 0875, from value 0 to 69. 0...67
0893 Digital input9
I parset bit1
1
As for parameter 0875, from value 0 to 69. 0...67
0894 Digital input10
I parset bit2
1
As for parameter 0875, from value 0 to 69. 0...67
0895 Digital input11
I parset bit3
1
As for parameter 0875, from value 0 to 69. 0...67
0881 Function, relay O no fault 1
As for parameter 0875, from value 70 to 97. 70...97
0467 Mode, relay output Supplementary parameter for P0881 Relay, direct 1
0 = relay direct
1 = relay inverted
0...1
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01