3-91
Confidential
(8) TCF transmission/reception
(9) Signal isolation
(10) Video signal reception
*Available in German models only.
Code 1 Code 2 Cause
80 01 Fallback impossible.
Code 1 Code 2 Cause
90 01 Unable to detect video signals and commands within 6 seconds
after CFR is transmitted.
90 02 Received PPS containing invalid page count or block count.
Code 1 Code 2 Cause
A0 03 Error correction sequence not terminated even at the final
transmission speed for fallback.
A0 11 Receive buffer empty. (5-second time-out)
A0 12 Receive buffer full during operation except receiving into memory.
A0 13 Decoding error continued on 500 lines or more.
A0 14 Decoding error continued for 10 seconds or more.
A0 15 Time-out: 13 seconds or more for one-line transmission.
A0 16 RTC not found or carrier OFF detected for 6 seconds.
A0 17 RTC found but no command detected for 60 seconds or more.
A0 19 No video data to be sent
A8 01 RTN, PIN, or ERR received at the calling terminal. *
A9 01 RTN, PIN, or ERR received at the called terminal. *
AA 18 Receive buffer full during receiving into memory.