APPENDIX 3 FIRMWARE SWITCHS (WSW)
A-34
WSW29 (Function setting 7)
Selector
No.
Function Setting and Specifications
1
|
8
Not used.
WSW30 (Function setting 8)
Selector
No.
Function Setting and Specifications
1
|
3
Not used.
4
Duty cycle control of pulsed current
for the heat-fixing unit
0: OFF 1: ON
5 Not used.
6
|
8
Not used.
NOTE:
Selector 4 is applicable to the European version only.
z Selector 4: Duty cycle control of pulsed current for the heat-fixing unit
Setting this selector to "1" activates the duty cycle control that suppresses the rush current.
The duty cycle is 10-ms ON and 20-ms OFF.
However, the duty cycle control may emit switching noise to the AC line. Depending upon
the codes and regulations in the country, this selector should be set to "0."