The oil level in the tank must not drop below the end of suction pipe, otherwise
air will be sucked in again.
Step
Procedure
1
Turn engine by hand in direction of engine rotation to return the oil from the
oil from the oil tank into the engine and into the collection container. The
procedure is complete when no more contamination can be discovered.
2 Control the oil captured during the rinsing process. The rinsing process is
complete when no more contamination can be discovered.
3
Re-install cleaned oil lines and oil cooler according to the manufacturers
instruction.
4
Install new oil filter and refill with oil.
5
Purge oil system.
Reconnect negative terminal of aircraft battery.
See Chapter 12–20–00 section Purging of the oil system.
Equipment
ATTENTION
Equipment is to be inspected in accordance with the Maintenance Manual of the
aircraft manufacturer.
12–20–00
Page 52
January 01 2020
Effectivity: 912 Series
Rev. 0

Table of Contents

Other manuals for BRP ROTAX 912 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP ROTAX 912 Series and is the answer not in the manual?

BRP ROTAX 912 Series Specifications

General IconGeneral
BrandBRP
ModelROTAX 912 Series
CategoryEngine
LanguageEnglish

Related product manuals