BRP-Rotax
MAINTENANCE MANUAL LINE
Authorized
exceeding
Extension or exceeding of the TBO by 5% or 6 months is allowed, whichever comes first.
Shipment The shipment to an authorized ROTAX® overhaul facility must include the following:
1 Engine log book.
2
Maintenance records of the engine (i.e. all maintenance check lists, and re-
ports of operation, of maintenance, of findings and of oil analysis).
3 The engine assembly as per supply volume. Additionally all added-on parts
as in the supply volume such as filters, intake silencer, fuel pump, external
generator, sensors, ignition unit, electric starter, oil tank.
4
Indication of total engine operating hours (TSN) and where applicable, en-
gine operating hours since a previous overhaul (TSO).
NOTE
This information must be supplied to allow the service history of
components to be traced.
5
Data about the type of aircraft used.
6
Useful remarks and observations concerning the engine.
05–10–00
Page 6
January 01 2020
Effectivity: 912 Series
Rev. 0