BRP-Rotax
MAINTENANCE MANUAL LINE
0.5 bar
(7.3 psi)
Operating limit
(See Operators Manual 912 Series)
Proceed as instructed
in table 6
Proceed as instructed
in table 5
0
1 min. Time
Figure 5.15
Oil pressure below minimum oil pressure on the ground
If noticed on ground, immediately stop the engine and determine the cause.
Inspect the complete lubrication system, trace cause and rectify.
See Service Instruction SI-912-005, latest issue.
If the oil pressure falls below the minimum value up to max. 0.5 bar (7.25 psi) and for max.
1 min., the cause must be determined.
Table 5: Oil pressure below minimum permissible oil pressure up to max. 0.5 bar
(7.25 psi) max. 1 min. in flight
Step
Procedure
1
Inspect all oil lines for restrictions and clear passage.
2
Verify oil quantity.
3 Inspect pressure sensor and connector.
4
Inspect indicating instrument to specifications of the manufacturer, replace
as required.
5
Inspect crankcase pressure (See Installation Manual, latest issue.).
Effectivity: 912 Series
Rev. 0
05–50–00
Page 27
January 01 2020

Table of Contents

Other manuals for BRP ROTAX 912 Series

Related product manuals